Okidata Oki B 411D
does the fuse blow when the drum is first installed?

How to Identify and Fix Common printer Problems ?

Our sources include academic articles, blog posts, and personal essays from experienced technical support :

“DRUM LIFE” or “REPLACE DRUM” is a rough indicator that the image drum cartridge has reached the end of its life. If there are no problems with print quality even if this message appears, continue to use until there is no toner left. When out of toner, replace the image drum cartridge and toner cartridge together.
Description. Image drum is designed for use with Oki Data C330dn, C530dn, MC361 MFP and MC561 MFP. Drum lasts up to 20,000 pages.
You`ll know the drum is dirty if you notice that the print quality has become blurry and features blank spots or oddly-colored spots despite having full toner cartridges. Horizontal lines across the printout when the paper passes over a dirty area are another sign that it`s time for some maintenance.
The image drum can print approximately 50,000 sheets of A4-sized paper (for simplex printing), but the actual printable number of sheets may vary with the usage condition. The above number is based on the general usage condition (three sheets at a time).
Shelf life is a period of time the components can be stored and still be suitable for use. A laser printer drum`s shelf life is approximately two years if the drum is still in its protective bag. Leave your printer`s drum in its protective bag until you`re ready to install the component.
There are many factors that determine the actual drum life, such as the temperature, humidity, type of paper, type of toner used, number of pages per print job and so on. Under ideal conditions, the average drum life is estimated at approximately 12,000 pages.
What is the drum unit? The drum unit transfers the toner to the paper. The laser printer puts the toner on the roller called “The photosensitive drum” inside the drum unit, and then prints letters and images by fixing toner to the paper by heat and pressure.
Test the cables and pads

The first step in the troubleshooting process is to check the cables and pads. Disconnect and reconnect the cable and ensure you insert it all the way. If that doesn`t work, connect the cable from the faulty trigger to a working pad. If the pad triggers, that means the cable is working.

Printer drum repair is an important service that requires knowledge and experience to complete in order to restore your printer. It includes troubleshooting printer drum problems such as HP, Brother and others, cleaning printer drum cartridges, replacing printer drum 88a and buying printer drum cleaning.
You can set when to display the “Image Drum Near Life” message. Press [Device Settings] > [Admin Setup] > [User Install] > [Drum Near Life Timing] on the touch panel to change the setting. Available values are from 500 to 3,000 (in 500 increments).

Relevant Questions and Answers :

the most relevant questions and answers related to your specific issue

HP 2840 All-in-one ,image drum counter reset
ANSWER : Hi, My HP 2840 is showing replace supplies on all but black , to print color all I have to do is send print command before the printer shows ready and it will print full color , also the windows test print works at any time ? It’s a pain but it works !

Read Full Q/A … :

Okidata Oki B 411D

reset toners and image drum life
ANSWER : They both have chips that need to be replaced. There are videos on YouTube that show how to refill the toners and how to replace the chips.

Read Full Q/A … :

Okidata Oki B 411D

Toner dots fused to drum
ANSWER : You can try alcohol on a cotton pad to remove the toner. Wipe dry afterwards. If the drum does not have nicks in the coating, it should be OK.

Read Full Q/A … :

Okidata Oki B 411D

image drum message
ANSWER : You don’t have to replace it until it wears enough to affect the print quality. You’ll get spots or stripes. Here you go on a free reset. If you read the thread, someone says the procedure also works on your model. http://www.fixyourownprinter.com/posts/33634

Read Full Q/A … :

Okidata Oki B 411D

RESET OKIDATA TONER DRUM
ANSWER : HI there, oki image drums contain a fuse. You can reset them if they are working/printing ok by replacing the fuse. Hope this helps. The fuse is located inside the unit so is a bit fiddly.

Read Full Q/A … :

Okidata Oki B 411D

Drum reset
ANSWER : This forum thread covers the reset procedure

Read Full Q/A … :

Okidata Oki B 411D

replace imaging drug
ANSWER : Open the top lid. Grab the handle in the middle of the drum and pull up.

Read Full Q/A … :

Okidata Oki B 411D

oki c511 drum reset, toner reset, turkey chip reset
ANSWER : If you switch off toner control, you should keep an eye on your prints, and we aware of ink quality, so filling colours as they’re emptying. Nevertheless, it’s an small disturb for the a,ount of money you’re saving ┬┐isn’t it?

Read Full Q/A … :

Okidata Oki B 411D